Expert Lab Ukraine LLC will help you to obtain a permit or declaration to perform high-threat works or to operate (use) machines, mechanisms, high-threat equipment, as well as to declare compliance of the company’s material and technical resources with the requirements of the legislation on labor protection.

Experienced specialists of our company will prepare a package of documents and receive an appropriate permit or declaration.
The permit is valid for 5 years, and the declaration is issued indefinitely.
Terms of receipt – 20 working days.

List of documents:

  • Extract about the state registration of the enterprise.
  • Help from the Statistics Department.
  • Taxpayer certificate.
  • Bank details.
  • Enterprise charter.
  • The staffing table of the enterprise.
  • Premises lease or ownership certificate.
  • Protocols and certificates of employee training.
  • Training of engineers and workers.
  • Medical examination certificates of employees of the enterprise.
  • Information about the availability of equipment at the enterprise.

We work on the official basis and issue following documents upon work completion:

  • the report of expert assessment of the state of labour protection and safety of the industrial production of the economic entity during the performance of the declared works;
  • the report of expert assessment of the state of labour protection and safety of the industrial production of the economic entity during operation of the declared machines, mechanisms and facilities and their compliance with the requirements of the legislation on labour protection and industrial safety;
  • the report of expert assessment of compliance of such machines, mechanisms and facilities with the requirements of the legislation on labour protection and industrial safety.

The expert assessment report – it is a document drawn up by an expert organization based on the results of expert assessment of the state of labour protection and safety of the industrial production of the economic entity in the form developed by the State Service of Mining Supervision and Industrial Safety of Ukraine and approved in accordance with the established procedure, which contains information about the compliance (non-compliance) of the assessed object with the requirements of the legislation on labour protection and industrial safety.

According to the legislation of Ukraine, the employee must stop operating machines, mechanisms and high-threat facilities in case of absence of technical inspection or expert assessment or discovery of defects that affect its safe operation.

EXPERT LAB UKRAINE LLC operates subject to Permit No. 239.19.30 of the State Labor Service of Ukraine (SLSU) dated 25.09.19 and provides a complete set of turnkey services for expert surveys of machines, mechanisms, equipment and high-threat facilities.

Our qualified specialists perform high risk works: technical inspection and trials (hydraulic (using water or other liquids), pneumatic (using air or inert gases); non-destructive testing: visual-optical (VT), ultrasonic (UT), capillary (PT); destructive testing: mechanical tests, determination of hardness), expert examination (technical diagnostics) of machines, mechanisms, high-threat equipment, namely:

  • equipment related to the production (manufacture), use, processing, distribution, storage, transportation, application, disposal or neutralization of flammable, explosive and hazardous substances of class 1 and 2, the mass of which is equal to or exceeds the threshold limits specified in the Regulation of the Cabinet of Ministers of Ukraine dated July 11, 2002 No. 956 “On identification and declaration of safety of high-threat objects” (The Official Bulletin of Ukraine, 2002, No. 29, p. 1357), (clause 1 of Annex 3 to the Regulation);
  • technological equipment and its elements of natural and liquefied gas supply systems of economic entities and settlements, industrial and inter-industrial oil and gas collection systems, oil and gas industry facilities, as well as gas-using equipment the power of which exceeds 0.1 MW (clause 2 of Annex 3 to the Regulation);
  • technological facilities of chemical, metallurgical, coke-chemical, foundry, oil-fat, essential oil, woodworking, food, processing and printing industries, chlorine and ammonia-using production sites (clause 6 of Annex 3 to the Regulation);
  • steam and hot water boilers with a heat output exceeding 0.1 MW (clause 9 of Annex 3 to the Regulation);
  • steam and hot water pipelines with an operating pressure exceeding 0.05 MPa and a heating temperature exceeding 110°C, pressure vessels operating at a pressure exceeding 0.05 MPa, with the exception of automobile gas cylinders which are tanks for gas motor fuel. (clause 10 of Annex 3 to the Regulation);
  • hoisting cranes and machines, elevators, escalators, lifts and cradles for lifting workers (clause 11 of Annex 3 to the Regulation);
  • equipment with a voltage exceeding 1000 V (electrical equipment of power plants and networks; process electrical equipment)
No. List of tests and measurements (the name of the measured object or tested electrical equipment, protection means and devices) Regulatory document with reference to the clauses governing testing and measurements
1 Power transformers and auto transformers “Rules of technical operation of electric installations of consumers” (RTOEIC), Annex 1, Table 1, Clause 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 21, 22
2 Semiconductor converters RTOEIC, Annex 1, Table 2, Clause 1.2. 3 а). 3 b). 3 c). 5. 6. 8. 10
3 Power capacitors RTOEIC, Annex 1, Table 3, Clause 1.2. 3. 4. 5
4 Cable lines RTOEIC, Annex 1, Table 5, Clause 1.2. 3 а). 9
5 Contact connections of collecting and connecting buses, wires and lightning protection cables RTOEIC, Annex 1, Table 7, Clause 1 b)
6 Suspension and support insulators RTOEIC, Annex 1, Table 8, Clause 1.2. 3
7 Inputs and lead-in insulators RTOEIC, Annex 1, Table 9,Clause 1.2. 3
8 Oil and electromagnetic switches RTOEIC, Annex 1, Table 10, Clause 1. 3. 4. 5. 6. 7. 8. 9. 10
9 Air switches RTOEIC, Annex 1, Table 11, Clause 1.2. 3. 4. 5. 6
10 SF6 switches RTOEIC, Annex 1, Table 12, Clause 1.2. 3.4. 6. 7. 8. 9
11 Vacuum switches RTOEIC, Annex 1, Table 1З, Clause 1. 2. 3.4. 5. 6. 9
12 Load interrupter switches RTOEIC, Annex 1, Table 14, Clause 1. 2. 3, 6, 7. 8. 10
13 Disconnectors, short circuities and releasers RTOEIC, Annex 1, Table 16, Clause 1.2. 4. 6. 7
14 Valve arresters and surge suppressors RTOEIC, Annex 1, Table 17, Clause 1. 2. 4. 5. 6. 9
15 Current limiting dry reactors RTOEIC, Annex 1, Table 19, Clause 1.2
16 Measuring transformers RTOEIC, Annex 1, Table 20, Clause 1.2. 3. 4. 7. 8
17 Internal and external switchgear RTOEIC, Annex 1, Table 21, Clause 1. 2. 4
18 AC electric motors RTOEIC, Annex 1, Table 22, Clause 1. 2. 3. 4. 6. 9
19 DC electric machines RTOEIC, Annex 1, Table 23, Clause  1; 2; 4
20 Grounding devices RTOEIC, Annex 1, Table 25, Clause 1. 2. 3. 6. 8
21 Electrical installations, devices, secondary circuits and wiring with a voltage up to 1000 V RTOEIC, Annex 1, Table 27, Clause 1.2. 3.4. 5. 7
22 Relay protection, electro-automatics and secondary circuits RTOEIC, Section VII, Chapter 6.

GKD 34.35.603-95 “Maintenance of relay protection and electro-automatics devices of 0,4-35 kV electrical networks. The rules”.

GKD 34.35.603-95 “Maintenance of relay protection devices, anti-emergency automatics, electro-automatics, remote control and signaling devices of 110-750 kV power plants and substations. The rules”.

EXPERT LAB UKRAINE LLC provides services all over Ukraine.